Bob January 23, 2020 for Model Number WMH31017AW-4 Whirlpool microwave The stove top light won't turn off. Is there a switch I could replace ?
1 Answer Bob, the hood lamp not turning off is going to indicate that the main control W10810046 has a stuck relay. This can be tested by unplugging the microwave and testing the main control from the yellow wire at EP2 pin 3 to the brown wire at EP1 pin 4 for continuity. If there is continuity, the control has failed and would need to be replaced. Read More...
Duncan November 17, 2018 for Model Number MMV6190DS1 Microwave works intermittently. When door is opened, the light doesn't always come on. When try to start microwave, message on control panel says door is not closed. We open and close the door several times and finally the light comes on and we're able to start the microwave. We think it is a door switch problem, but want to make sure we order the correct parts for our model.
1 Answer Duncan, For this issue the most likely cause would be a interlock that is faulty. Also you will want to check the door switches to make sure that they are good. You will need to test the switches for continuity. Read More...
Raymond January 31, 2018 for Model Number MH1150XMB-2 Changed light bulb and the light will not still come on. the fan works and everything else works.
1 Answer Hello Raymond. This would indicate the control board 8206448 has failed on the unit. Thank you. Read More...
Rod T September 18, 2017 for Model Number WMH53520CB2 What is the part number for the fan switch. I will need to order one
1 Answer Hello Rod. The fan gets its power from the main board in the unit. You will need to order WPW10678766 for the main board needed. Thanks. Read More...
R.D. February 19, 2017 for Model Number WMH53520AB1 Since new, I must push hard on the door before it will start, My wife just slams it shut over and over to get it to start. What do I need? I am tired of hearing it slam.