Customer Questions and Answers for Refrigerator Defrost Timer by Whirlpool

Best Seller
Manufacturer Part
4.89 (64)
By: Whirlpool
Part Number: OEM17955633
Manufacturer Part Number: W10822278

Fixes ice buildup on freezer coils and warm fridge temps. This defrost timer regulates the automatic defrost cycle. Moderate DIY repair with video guide.

More
$34.75

IN STOCK
Ships Tomorrow Guaranteed
Add to Cart

Questions & Answers

For Whirlpool Refrigerator Defrost Timer (Part Number: OEM17955633)

1 Answer

Hello L.S.,

There are a couple of things to check in order to determine the issue. First and simplest, are both the freezer fan, (evaporator fan), and the fan behind the unit, (condenser fan), running? If not, this is the issue. If they are running, you need to make sure the hot coils, (condenser coils), are clean. If they clog with lint, the unit cannot cool down to temperature. If these things check out, you will need to remove the rear wall of the freezer and check the frost pattern on the evaporator coils. You are looking for a frost pattern that is fairly even from top to bottom. It will always be a little heavier near the top, but if the bottom of the coils are free of any frost, the issue is in air circulation or within the sealed system. The thing you don't want to see is an ice ball at the point where the lines come into the freezer compartment, since this is an indication of a freon loss. From this point, we need to know what you have found so we can further pursue the problem.

Read More...

1 Answer

Hello Curt. It sounds like you may have a defrost problem with the unit. Check and see if there is any frost build up on the back wall of the freezer. If so, you will need to test the defrost heater and the defrost thermostat. They should read closed for continuity when cold. You can test this with a multi-meter TJMA-DMT3. I will include a link at the end to assist you how to use the multi-meter if needed. If both parts are good, you will need to replace the defrost timer. Once the problem is repaired, you will need to thaw out the ice on the coils before the unit will operate properly. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html

Read More...
Bob for Model Number 106 50562990

My fridge stopped running. It had been off quite a while and both sides were warm. I hit it near the location of the cold control and it started again. The fridge ran until it reached the temps that it normally would and switched off. AGAIN, it would not switch back on, so I hit it again and it began running. Once again, after it cooled and turned off, it will not start again. I was going to order a cold control, but I was asked on the chat line if my defrost timer is working ok. How do I check it to find out? I have a ohmmeter.

1 Answer

Hello Bob. The timer is not going to cause the issue you are having. Based on the information you provided, it is the cold control WP2198202 that is bad and will need to be replaced.

Read More...

1 Answer

Hello Karl,

You would not need to bend any tabs on the timer and the black lead will go over terminal #2.

Read More...

1 Answer

Gary, Since this refrigerator has a "static" condenser, you'll need to slide it out and check and clean the tubing on the back, and remove any debris in the area. The room temperature has a lot to do with the "run time" as well, if the refrigerator is in the garage, basement, or a non heated area, the exchange of heat is less efficient and the compressor runs longer, as well as "overloading" the compartments. The click noie every so often, could be the overload on the compressor "closing" or opening, due to the compressor overheating, due to lack of air movement low voltage or extended run time.

Read More...

1 Answer

Hello,

The black wire should be attached to terminal number 1 (OR) in order for it to go into defrost every 8 hours.

Read More...

1 Answer

Hello Mike. Based on the model number, For cumulative run timer
push slotted loose timer
motor lead over & all the
way down terminal
number 2 with wire
toward timer motor.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google