James H December 31, 2014 for Model Number WGD5550SQ0 While testing I am only getting 29 volts AC to the glow coil, traced back to thermal switches with no improvement of power. I presume I am loosing the power at the timer output terminal. The thermal disks all have continuity. Am I right right to think the power loss in in the timer?
1 Answer James, Yes, the power loss will most likely be caused by a faulty timer which is part number WP8299765. Read More...
Litov September 11, 2013 for Model Number mgd5600tq0 maytag gas dryer My dryer does not dry clothes completely in auto dry. It will run with heat for a short time and then continues to run cold endlessly. I have cleaned the exhaust and installed a new vent duct. Also, I have replaced the thermal fuse and the cycling thermostat but the symptom remains the same. Please help.
1 Answer Hello Litov. It sounds like the gas coils 279834 are bad and will need to be replaced on the unit. This will cause the unit flame and not restart during a cycle. Read More...