Fred May 20, 2023 for Model Number NGD4655EW3 What would I test my timer for if my unit will not go through any cycle?
1 Answer Fred, If the unit will not power on at all then you need to test to see if there is voltage to the unit and to the timer. Read More...
Greg May 20, 2023 for Model Number VGD6505GW0 I used a multimeter to confirm continuity of the thermostats plus the igniter and they all worked so what would cause not heat?
1 Answer Greg, if the ignitor does not glow when a cycle is started, the power cord would need to be unplugged and the timer W10857611 would need to be tested for continuity from terminal C to terminal A when the timer is set to a heating cycle. If there is not continuity, the timer has failed. Read More...
Bill V. August 19, 2021 My Amana dryer will not shut off. When you set the timer it just runs until you shut it off manually.
1 Answer Hello Bill, I'm sorry but we will need to ask you to post a new question including the model number from your units' I.D. tag so we can provide a proper diagnosis and recommend parts that can be guaranteed to work properly on your unit. Thank you for your patience and understanding in this matter. Read More...
Earl L. August 13, 2016 for Model Number NGD4600YQ0 The dryer will initially go through its cycle with no problems. The igniter heats up, flame sensor kicks in, the gas valves open up and gas ignites. The dryer will run its cycle maybe two times and won't heat up anymore until a couple of hours later. The hi-limit thermostat, thermal cut out, the cycling thermostat, and thermal fuse had continuity.
1 Answer Hello Earl, This will be either a failed coil WPW10328463 on the gas valve or the gas valve 279923 itself has failed. Read More...