Questions & Answers

For Whirlpool Ice Maker Control Transformer Assembly (Part Number: OEM18021606)

1 Answer

Hello Gary, thank you for contacting Appliance Parts Pros.
[WP2310139] is not a display transformer, it supplies low AC voltage to several other components like the recirculation pump and reservoir drain pump. It should have 120v AC incoming on the Black and White wires, w/ 8-9v AC from Yellow w/ Blue tracer to Yellow and 11-13v AC from Red w/ Black tracer to Gray on the outgoing side.

Read More...

1 Answer

John,
The transformer does have power to it any time the machine is plugged in so it could be a little warm to the touch.

Read More...

1 Answer

Johnny,

The cutter grid is very low wattage and should not be really hot. You should be able to touch the cutter grid and hold your hand on it. The ice should drop down onto the cutter grid after it forms on the plate. If it is not then you will want to check the thermistor on the bottom of the ice plate to make sure that the thermistor is good.

Read More...

1 Answer

Klane,

You will want to test the transformer on your unit to make sure that it is good. If the transformer checks ok then the issue will be the control board.

Read More...

1 Answer

DKG,

Yes the transformer can cause the controls on the unit to not work. You can test for 120 vac going in to the transformer and then test for 12-24 vdc coming out of transformer to make sure that it is working. If there is power in but not out then replace the transformer. IF there is no power in the check back from the transformer back to the power supply cord to ensure good wiring.

Read More...

1 Answer

Paul, 8 to 8.4 volts DC is the correct voltage range for the cutter grid circuit from the control board. The cutter grid assembly should have a resistance reading of 4(four) to 5(five) ohms resistance if it is intact, It sounds like it is operating properly at this point.Perhaps someone has adjusted the cube size to a thicker setting ?

Read More...

1 Answer

Hello Jeff,

If you are getting 22 vdc then your transformer [AP3956373 is defective and would need to be replaced. You should have no more than 13.2 vdc coming to the pumps.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google