Ernie for Model Number PH36GS/04 1. Rt side halogen light goes off but tapping it turns it back on, replace bulb and socket? Pn? 2. Both halogen lights come on but do not dim even though the led say they are on. Replace transformer pn? 3.Now unit comes on all by itself and cycles repeatedly thru lights, fan, off and can not be stopped. Turning power off and on does not reset, unit just starts the cycle again. Replace 8 button control board pn? 1-off 2-fan speed 3-auto 4-delay 5-filter reminder 6- light on/dim/off 7-heat lamp lt 8- heat lamp rt 4. How do I remove and replace the 8 button panel?
Answer Ernie, it is possible that the halogen bulb is not inserted fully or there may be a wiring issue. The part number for the bulb and socket is [00620803]. Based off of the wiring diagram the main control [00655614] should be what is sending voltage directly to the lamps and would be responsible for dimming them. The main control is also more than likely going to be responsible for the cycle being repeated. The controls can be accessed by removing the filters and removing the retaining nuts on the inside of the hood. It is recommended to do this with the unit unplugged. Read More... Answered by AppliancePartsPros.com | Wednesday, March 6, 2019