Skip to Content
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • lovely images 15 million satisfied customers
  • boxes images Over 2.1 Million Parts In Stock
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store

Customer Questions and Answers for Control Module by Frigidaire

4.89 (64)
By: Frigidaire
Part Number: OEM13177896
Manufacturer Part Number: 154712101

Questions & Answers

For Frigidaire Control Module (Part Number: OEM13177896)

View all Questions

Answer

Hello Steve, The clean light blinking 7 times is a fault code for the water heating circuit on board the unit. If the control doesn't see a predetermined increase of temperature in a set amount of time, the code will flash. First off, be sure you always run the hot water at the sink before starting a cycle to shorten the wash cycle. The most probable cause of this fault code is the heating element going open. Other possible causes are the door switch WP8269209, the control board WP8564543, the Hi-limit thermostat WP661566, and the wiring harness. Of course the first thing I would recommend is to visually inspect the heating element Heating element kit- This dishwasher heating element is for stainless steel tubs only. Includes a new computer board that needs to be replaced along with the element. For plastic tubs use W10518394. Part Number: 8194200 . If it has burned in to of course it will need replacement. If there is a white place, or much lighter place present it will need to be tested to ensure your not replacing a good part. You can test this with a multi-meter TJMA-DMT3. Here is a link on how to use a multi-meter. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html . The wiring diagram should be found behind the kick panel and will guide you to the fore-mentioned components which you may need to test. After repair you will also have to place the unit into the diagnostic mode to reset the control so it can run through cycles again. This procedure is as follows: On the control panel....heated dry,normal,heated dry,normal - OR - High temp,air dry,high temp,air dry. These keys must be pressed within 10 seconds to set the control into diagnostics. At this point you can allow it to go all the way through the self-diagnostic cycle or you can press cancel.

Read More...

Answered by AppliancePartsPros.com   |   Thursday, July 26, 2012

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro

Share your thoughts with other customers

Answer or comment
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store