Answer Hello A.P., The solenoid WR62X23154 beside the auger motor is most likely frozen. If blowing a hair dryer on it for about 10 to 15 minutes restores operation the issue is normally an air leak at the ice door caused by a rusted ice door solenoid WR62X10055. Read More... Answered by AppliancePartsPros.com | Thursday, November 5, 2015