Skip to Content
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Trusted Since 1999 Trusted Since 1999
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google

Customer Questions and Answers for Refrigerator Dispenser Control Touchpad by Ge

4.89 (64)
By: Ge
Part Number: OEM13088709
Manufacturer Part Number: WR55X10859

Fix unresponsive ice or water dispenser buttons with this control touchpad. Simple 15-minute snap-in replacement—disconnect power, unsnap old part, reconnect wires.

More
$178.52

IN STOCK
Ships Today Guaranteed
Add to Cart

Questions & Answers

For Ge Refrigerator Dispenser Control Touchpad (Part Number: OEM13088709)

View all Questions

Jeff for Model Number GSS25QSTASS

The bulb in the dispenser glows very dim (only filament glows slightly) when the light control button is pressed in the panel. Thinking there was a problem with the socket, I replaced the socket with a new one I just purchased from you, however the same problem is happening. I tested the bulb in a nightlight and it works fine. The bulb is the correct one for the unit. It's almost as if not enough energy is getting to the socket to fully illuminate the bulb? I have removed the existing panel and tested all the connections. Problem persists. Could there be a problem with the panel itself requiring an entirely new control board? Could it be the wiring from one of the three wire connections, and, if so can I only buy the new wiring rather than having to buy the entire panel for $140? Please let me know your thoughts. Thank you.

Answer

Jeff, you will want to remove the ice bin and then set the dispenser for ice. From there you will want to gain access to the wire connection to the bulb socket and test for 12VDC from the red wire with the red probe to the yellow wire with the black probe of a multimeter TJMA-DMT3 while the dispenser paddle is engaged. If there is not around 12VDC, then the display would need to be tested at the same wires directly connected to the display. If 12VDC is not being sent by the display WR55X10859, the display would need to be changed out. If the display is sending the voltage, then the most likely failure would be the dispenser switch WR23X10783 not properly engaging to send voltage to the bulb.

Read More...

Answered by AppliancePartsPros.com   |   Monday, June 24, 2019

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro

Share your thoughts with other customers

Answer or comment
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google