Maryshka for Model Number GSE23GGEBCBB My freezer/refrigerator was thawing. I replaced the evaporator fan motor. Freezer/refrigerator was getting cold but not cold enough. Realized I did not clip the thirmoster to anything. Took everything apart again and clipped the thirmoster onto the silver pipe. Now freezer is getting cold but seem to be stalled at 15 degrees in the freezer and 40 degrees in the refrigerator. Does it matter if I clip the thirmoster to the silver pipe and not the copper pipe? I've watched a few videos and saw it clipped to both depending on the video. If it does matter, then that may be why the temperature isn't going any lower. If it doesn't matter, what should I try next?
Answer Hello Maryshka, the thermistor that clips to the evap coil is only used in the defrost cycle, either location on the coil is acceptable.If the condenser fan,evap fan and compressor are running and the ref seems to run nonstop and the freezer cannot cool down below 15 deg then that may indicate a sealed system problem, Read More... Answered by AppliancePartsPros.com | Thursday, June 2, 2022