Coguy for Model Number LFX25960ST My ice maker will perform all functions through a test except fill with water at the end of the cycle. I have replaced both valves and confirmed no blockage of the water line. When it “calls” for water, the solenoid in the door valve activates, but the main valve solenoid (at the back of the fridge) does not. Any suggestions?
Answer CoGuy, as the ice maker is able to enter into a forced harvest and the secondary valve activates, the failure would most likely be in the main control EBR34917104. Read More... Answered by AppliancePartsPros.com | Thursday, October 22, 2020