Fix error codes, dispenser failures, or temperature issues with this main control board. DIY-friendly repair typically takes 10-15 minutes to install.

More

Questions & Answers

For Lg Refrigerator Main Electronic Control Board (Part Number: OEM13350657)

Mike for Model Number LG LFX25960ST

main control board stopped working. Un plugged and plugged back in and it makes a quick high pitch noise and then nothing. replaced with a used board and it rand for about a week. but makes a high pitch noise when multiple fans are running. See the video at https://photos.app.goo.gl/yTweGHNitV3CufMQA. Any ideas. I checked the load from the fan motors and then are all withing spec. I replaced the front PCB as well. Did I just get a worn out board the second time??

1 Answer

Mike,

This issue sounds likely that the control board is faulty. When replacing the control board it is best to install a new one. It would be best to go ahead and get an OEM control board that is new.

Read More...

1 Answer

Yawo,

Test to see if the fans are getting 12 vdc to them and if they are not then the main control board will be the issue. If there is power to them then replace the fans.

Read More...
Guy for Model Number 79577569600

woke up to refrigerator beeping, not cooling and fridge interior light not working (freezer lights did work and was cold) unplugged and reset, now get ER dH code. found that main board is not putting out voltage to defrost heater when in test mode "3". Per TECHNICAL DATA sheet that came with fridge, requires part # EBR34917102 main control board...However back in 2009, the refrigerator lights stayed on, and under warranty the main control board along with the light assembly and other parts, where replaced. I still have that invoice and it has listed main control board part # EBR34917104, however the part number on the board installed is EBR34917109. I understand the 104 replaces the 102, but do not see any info about the 109 replacing either of the other. I see you stock both part numbers, Do you have any info on the 109 as being a replacement for the others and suggestions to which I should order ? Thanks (fridge s/n 612KR00166)

1 Answer

Nancy,

With nothing on the unit working, this will most likely be a faulty main control board.

Read More...

1 Answer

Pat,

The error codes that you are getting will pertain to the icemaker fan and icemaker sensor not working. For the freezer section not working you will want to check to make sure that the fan in the freezer is working and that the evaporator coils have a nice even frost pattern from top to bottom. If it does not then this may be a sealed system issue and would require a technician.

Read More...
Tw for Model Number 795.73132410

Freezer part of fridge was intermittently working, sometimes close to 0°F other times closer to 30°F. Had a repair done and the compressor was replaced (qualified Sears tech). Was not cooling after the repair so I checked the PCB board and noticed a 6 flashing light code (did not do that before). I ran through the 3 step diagnostics, unplugged the fridge for 15 mins, and restarted. The freezer got cold (down to about 5°F) for about 24 hours then warmed back up, warmer than before the repair. The PCB light is again flashing 6 times. Is it possible a bad compressor was installed (it sounds OK), it was a bad install (leak) or did the install possibly damage my PCB board somehow? PCB board was supposedly updated as part of the repair. Some guidance here would be appreciated before I decide the next steps. Thanks

1 Answer

TW, the 6 blinks is going to indicate that there is a sealed system issue, likely a leak, that would require a freon certified technician to diagnose and repair.

Read More...

1 Answer

Charles, usually if there is a major failure in the compressor TCA38151706, the main control EBR79267107 will have a blinking LED that will indicate a failure. Depending on what the flash pattern is, it can tell if there is a failure in the compressor or the control.

Read More...

1 Answer

CoGuy, as the ice maker is able to enter into a forced harvest and the secondary valve activates, the failure would most likely be in the main control EBR34917104.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google