Tw for Model Number 795.73132410 Freezer part of fridge was intermittently working, sometimes close to 0°F other times closer to 30°F. Had a repair done and the compressor was replaced (qualified Sears tech). Was not cooling after the repair so I checked the PCB board and noticed a 6 flashing light code (did not do that before). I ran through the 3 step diagnostics, unplugged the fridge for 15 mins, and restarted. The freezer got cold (down to about 5°F) for about 24 hours then warmed back up, warmer than before the repair. The PCB light is again flashing 6 times. Is it possible a bad compressor was installed (it sounds OK), it was a bad install (leak) or did the install possibly damage my PCB board somehow? PCB board was supposedly updated as part of the repair. Some guidance here would be appreciated before I decide the next steps. Thanks
Answer TW, the 6 blinks is going to indicate that there is a sealed system issue, likely a leak, that would require a freon certified technician to diagnose and repair. Read More... Answered by AppliancePartsPros.com | Sunday, August 8, 2021