John for Model Number RF260BEAESR/AA My French door Samsung refrigerator has been working for three years. Now it does not cool at all, and it gives the error code 84 E, which seems to be for "Locked Compressor". Also, in the Inverter PCB, the LED Blinking Frequency is 4 (blinks four times between pauses), which again seems to be "Locked Compressor". I found on line the service manual for this model and did some measurements. All three winding of the motor were equal, 12 ohm. Resistance windings-ground is indefinite. Disconnected three wire connector in Invertor PCB that powers the compressor. Still the error code 84 E, and four blinking of LED. Measured the AC voltages that enter the Invertor PCB and the Main PCB: It was 120 Volt. Measured the DC voltages that enter the Invertor PCB from the Main PCB in the 7 pin connector: Pin 5 and 6 are ground. Pin 1 to 5 -13.2 V, Pin 2 to 5 – 13.2 V, Pin 3 to 5 – 5 Volt. Fuse is good. Disconnected all connectors from all three PCBs. Removed Main PCB and Invertor PCB; no visual damage on both sides of each one. No current draw with all connector disconnected. Plugged the first connector into the AC Entry Power PCB (small PCB). The current drew from the outlet was 0.05 Amp. Plugged one by one the connectors in the Main PCB. The current did not change: 0.05 Amp. Plugged into the Inverter PCB the 7 pin connector that supplies DC power from the Main PCB. The current did not change: 0.05 Amp. Pugged the AC power input connector into the Inverter PCB (but not yet the three wire connector that powers the compressor). After a couple of seconds the relay (in the Main PCB) clicked, and current from the outlet increased up to 3 Amp for a couple of seconds then the relay clicked again, the current dropped at 0.05 A, LED began to flash with frequency of 4, and code 84 E appeared. Removed power, plugged the three wire connector that powers the motor of the compressor, and powered up again. Happened the same as above. The compressor did not work. Used a digital and then an analog meter, in AC and DC range, to measure voltage between 3 wires that power the motor of compressor, but there was no indication of voltage at all (during the time period of powering up, relay clicking, and error code flashing). The frequency between these 3 wires was variable at first seconds then stabilized at about 5 KHz. Replaced the Inverter PCB with a new one. The same situation, error code 84 E, LED flash frequency of 4. Why it shows error code “compressor locked” even though the motor of the compressor is disconnected? What can be the reason why the compressor is not working?
Answer Hello John, The fault code description in the service manual is referring to a sealed system issue. When there is a sealed system restriction, too much pressure is built up on one side and it cannot bleed of to the other side inside the system, causing the compressor to lock, since it cannot build up any more pressure. This will most likely take a Freon authorized technician to diagnose and correct. Read More... Answered by AppliancePartsPros.com | Thursday, August 10, 2017