Jason for Model Number RF267AERS/XAA-01 The compressor will not come on. The fan will run. The first time this happened we bypassed to overload switch because it was bad. We ordered a new one because when we bypassed it the fridge worked. This time it will not work with the overload switch bypassed. The compressor tries to start but don't. I can hear the relay clicking when I unplug it and plug it back in. I also hear it click again after a little bit. The inverter led is blinking twice. it also flipped the breaker to the electrical outlet both times this happened. Would the problem be the inverter board or am I looking at a bad compressor?
Answer Jason, with the unit unplugged the compressor can be checked for resistance. The windings of the compressor should measure 10 Ohms when each pin is tested to the other pins. If the compressor windings test good, the issue would be with the inverter DA92-00111B if the wiring is good. Read More... Answered by AppliancePartsPros.com | Wednesday, October 9, 2019