Steve for Model Number RF261BEAESR/AA-0001 Hi I had my compressor and inverter board both replaced due to a power loss. The fridge (temp) is working fine, but the bottom freezer evap fan doesn’t come on at all. I have checked voltage at the terminal block and get a reading around 3 volts dc. The fan motor is fine as I hooked it up to. 9 volt battery. Also, I now have one solid red light showing on the inverter board which was not present before. No error codes on the panel. Any suggestions?
Answer Steve, " I now have one solid red light showing on the inverter board" indicates the board is operating Normally. The DC voltage to the freezer fan is low" Is the voltage between MAIN PCB Ground J23 JUMPER and CN 76 (Yellow) around DC7~12V? and Is the voltage between MAIN PCB Ground J23 JUMPER and CN76-(White) around 4.5~5V?. First check for loose connections and corrosion on the wire connections, then test the voltages at the main control board. Thanks, Read More... Answered by AppliancePartsPros.com | Sunday, August 16, 2020