April for Model Number RF267ABWP/XAA-0000 The energy saver light and alarm started going off and temperature started Rising. Ran self diagnostic and got fault code on each side of the display of 88. We unplugged the unit plugged it back in it appeared to be holding temperature, however there was a steady blinking light on the power inverter board, we unplugged the board and plugged it back in but now there is no led light on and the compressor is no coming on.
Answer April, the blinking light on the inverter would indicate a failure error code. It would be recommended that the forced test mode is activated to identify the blinking LED of the inverter if possible. Otherwise, the inverter can be tested for DC voltage using the connection CN10 at the main control. From the black wire (using the black probe of a meter), DC voltage would be tested at the red wire with the red meter probe for 5VDC and then the yellow wire with the red probe for 12VDC. If the voltage is correct, the main control DA41-00413J has failed. If the voltage is not correct, the inverter PCB DA41-00320A has failed. Unfortunately, the inverter has been discontinued and is no longer available. Read More... Answered by AppliancePartsPros.com | Monday, August 24, 2020