Gabriel for Model Number RFG237AARS Hello, The compressor for refrigerator Samsung RFG237AARS does not start, and the red LED on inverter board DA41-00411A flashes 5 times (low input voltage fault code). I checked that the 115V AC voltage is getting into the board, and the board generates the required internal DC voltages (5VDC, 15VDC, ~350VDC). However, there is nothing going out to the compressor motor, even though the main PCB provides 5V command to the inverter board for compressor activation. I replaced the inverter board with another board same P/N in used/unknown condition, and I am getting exactly the same behavior (red LED flashing 5 times, and compressor does not start). I did some research and found that inverter board DA41-00411A is discontinued, replaced by DA41-00614F. I don't know if I should purchase the new P/N, knowing that I got the same faulty behavior with two different boards of the original P/N. Can you help? Thank you
Answer Gabriel, based on the information provided, the compressor MKV190CL2B/ASH has failed and would require a freon certified technician to repair. Read More... Answered by AppliancePartsPros.com | Thursday, November 19, 2020