Patricia L for Model Number RF268ABRS/XAA-0000 The freezer in my 8 year old fridge stopped freezing and it was followed a couple of days later with the refrigerator not cooling. You could hear the compressor trying to start as it had a low pitched hum. This went on continuously until the repairman arrived and diagnosed it as compressor failure based solely on the noise it was making so I authorized him to order the part. A week later my friend asked to inspect it so I turned it on at the breaker and suddenly it was working properly (though I had done a 10 minute reset before the repairman). The friend pulled it out from the wall and took the lower panel off and inspected it anyway. Nothing obvious and compressor running. 4 days later it stopped again, first the fridge followed by the freezer. Left it running and had friend look again. Compressor making same low hum and occasional vibration noise. He checked the upper panel and it was blinking 2x. He was going to check the code. He reset it and the light went out and compressor started working properly. Next day it stopped cooling and freezing so I did an hour rest and it’s been running for 2 days. Repairman left a voicemail yesterday that the special order compressor has arrived and to schedule it’s replace. What are the chances this is the inverter and not the compressor and how do you test for it?
Answer Patricia, This 2 flashes indicate a restriction in the sealed system or a refrigerant being low. If this checks ok then the inverter would be the part to replace but still could be the compressor if the inverter does not correct the issue. This sounds likely that it would be the inverter instead of the compressor. Read More... Answered by AppliancePartsPros.com | Sunday, December 13, 2020