Jp for Model Number RFG298AARS Refrigerator and freezer will not cool and compressor not on. Inverter board blinking once. Checked power at CN75 on main board connection to inverter. Has .75 on brown wire, 0 on the red, and -4.1 on the orange. Have not checked relay at compressor. Suggestions? Thank you.
Answer JP, Based on the information and model number provided: One blink of LED = Test: Check the Inverter PCB & Comp Relay Connectors Replace: If the Connectors are OK, replace the Inverter PCB, if the same, replace the compressor. Read More... Answered by AppliancePartsPros.com | Tuesday, October 18, 2022