Mike for Model Number RF20HFENBSR/AA The problem with my refrigerator started when the top half would freeze up. (fresh food) I replaced the sensor and I am not sure if the inverter board is bad. I have ac going to it. Should the red light be on at all? Neither the compressor or fan comes on.
Answer Mike, you may want to try pressing and holding the power freeze and the freezer button at the same time for around 5 seconds to check to see if the display mode has been activated. The unit should chime after 5 seconds indicating the activation or deactivation of the display mode and if the compressor turns on then the display mode was activated. If the compressor does not come on, the process will need to be repeated to ensure that the unit is placed back into the original state. The inverter led should be on and solid indicating that it is receiving proper voltage. The signal voltage from the main control would need to be checked at connection CN73 on the main control. With the black probe of a meter on pin 3, the red probe would be placed at pin 4 to test for outgoing DC voltage signalling to the inverter to turn the compressor on. If there is not a pulsing DC signal, then the main control DA92-00420S has failed. If there is a DC signal, then the inverter DA92-00111B has failed. If there is a continuous clicking coming from the compressor area, this is an indicator that the compressor overload protector DA34-00004D is tripping due to an over draw on current from the compressor and can either be a failing overload or a locked up compressor. Read More... Answered by AppliancePartsPros.com | Tuesday, August 27, 2019