Leroy for Model Number WF316BAC/XAA No blockages in the hose & replaced the drain pump. My next part I looked at was the water sensor, I cleaned it & when I unplug it the cycle will continue with out draining. Does the sensor keep the pump from running or should I look a a different part(ie door switch or the relay board)?
Answer Leroy, you need to look elsewhere, most likely the control board. The water level switch doesn't control the drain pump, but it does control the spin cycle. The pressure switch has to reset to the empty position, This data tells the control the tub is empty of water and cam/should spin. Check for 120 VAC at the drain pump wiring from the control board. No voltage indicates a broken wire or bad control board. Read More... Answered by AppliancePartsPros.com | Thursday, December 10, 2015