Jay S for Model Number MFI2568AES Came home today and water and ice control panel had all light flashing and ice flapper was opening and closing. Power had been knock out by a storm and the temp was Hi inside the unit. Once the temp came back into range the flashing lights and the flapper stopped. Now every time the unit turns on the same thing happens. Disassembled the unit once I disconnect the power cable to the door heaters the unit was properly. The only thing is the water and ice does not dispense.
Answer Hello Jay. Based on the information you provided, you will need to order and replace part number W10890094 on the unit. Read More... Answered by AppliancePartsPros.com | Tuesday, February 4, 2014