Boy Rod for Model Number GC5SHEXNBOO Initial problem was its not getting cold. Found out condenser was all clogged up. Check compressor has no power and the compressor control board was toast. So I bought a new control board and install it. Compressor turns on but stays on. The condenser fan doesn't come on and the door sides are real hot. I guess the heating element are not kicking off too. Appreciate the help I can get.
Answer Boy Rod, You will want to check to make sure that the condenser motor is getting power. The issues that are occurring would come from the condenser fan not operating as the temp will not be right and the center mullion between the doors will get extremely hot. The compressor will run til it overheats due to the fan not running. Most likely will need a new condenser fan motor W10124096. Read More... Answered by AppliancePartsPros.com | Thursday, October 10, 2013