Ron for Model Number kuds301xbl7 The Circulator motor will not run. I replaced the motor, probably too soon, and the motor still will not run When you start a cycle, the unit fills with water, sounds like it tries to start the circulator three times, then pumps out the water and shuts down. What did I miss? Thanks for your help Ron
Answer Ron, if only the motor WPW10239401 was changed out and not the full motor assembly WPW10757217, the start capacitor WPW10334457 would need to be tested for 23.5 uf microfarads after having the unit unplugged for 10 minutes and using a rubber handled screwdriver to discharge the capacitor (having the screwdriver bridge the two terminals of the capacitor while the hand is only touching the rubber handle). If the capacitor fails, it would need to be replaced. If it does not fail, it would be likely that the main control W11035586 has failed if the motor impeller and motor shaft can rotate freely. Read More... Answered by AppliancePartsPros.com | Sunday, November 14, 2021