Robert for Model Number 66513153k701 Last year "normal wash" stopped halfway through giving 8-1 error (fill problem) Used instead "one hour wash" and no problem until now with blinking 1-8 code again (always at 20 minutes). I replaced fill-valve...no change. I ran a diagnostic wash-with-error-indication using a stopwatch. Several sequences yielded a steady green. At ten minutes, there was a brief drain and water was all out in a few seconds. Next, for three minutes was silence but the red run light was still on. At exactly thirteen minutes, red light went out, cancel light on, 3 minutes of dry drain motor running then 8-1 blink. It seems like the silent three minutes was a timeout from some action that didn't happen. I assume the fill function. I am considering control board possibly faulty. Is that surely it? Also, I have an old w10193578a board. The ribbon cable feels non-removable to finger-pull at control side. Is that true?
Answer Robert, You will want to first check the overfill switch to makes sure that it is not stuck, there could be something stuck under the float that could cause this issue. Also make sure that the drain loop has not come detached from the tub or an improper drain connection. Also check for leaks under the unit. If all this checks ok then the issue would be with the control board. Read More... Answered by AppliancePartsPros.com | Tuesday, December 16, 2014