Teemech for Model Number 106.89482995 I've just changed the evaporator on this unit. I push the Clean button for it's first cleaning. Then selected the On button on the control board, and everything is working fine. Until it completed it'e first harvest of ice. Now I found the Clean light blinking. Well, I started another clean cycle; then another Normal cycle. Again, after the ice harvested, I got a blinking clean light. It's got to be the control board; right?
Answer Hi Teemech. The green clean light may also mean that the condenser coils need cleaned. Use compressed air to insure they are cleaned. Make sure the condenser fan assy. part # W10822259 is turning up to speed and the fan blade is clean. On the rt.of the bin there is a bin thermister. The thermostat WPW10503764 can be tested for ohms with a meter. It should read around 10K at room temperature. You can test this with a multi-meter TJMA-DMT3. Thank You. Read More... Answered by AppliancePartsPros.com | Thursday, June 28, 2012