Dsquick for Model Number kuis18nnjb8 My ice machine seems to be stuck in defrost. I turn the machine on and the plates start heating up. No water is running. I can't even make water run if I put it into the clean mode. Any clues?
Answer Hello, This sounds like a sealed system issue. Sounds like the reversing valve 2208467 is stuck in the defrost position. The reversing valve reverses the circulation of the freon to cause the cold coils to become the hot coils for the harvest of the cubes. After the harvest cycle, the reversing valve is supposed to reverse the freon circulation again to cause the evaporator coil to get cold again. KUIS18NNJB8 Read More... Answered by AppliancePartsPros.com | Thursday, July 12, 2012