Greg H for Model Number zdis15cssn Hello, my ice machine turns on and water solenoid turns on and reservoir fills. It then overflows and stops a few minutes later. The machine made 2 bathes of ice and quite and went into filling the reservoir to overflow and thats it. Ice is very cloudy. Nothing happens from that point on. When in cleaning cycle the circulation pump will turn on and work. Is the circuit board the problem. Thanks, Greg
Answer Hello Greg, You will want to check both your bin thermostat and the evaporator thermistor. Both should read at 10K ohms at 77 degrees. If either checks bad then you will need to replace the thermistor. If these check ok then you would want to replace the control board. Read More... Answered by AppliancePartsPros.com | Wednesday, January 16, 2013