Andrew Funk for Model Number JDB8910AWS HI, My Jennair jdb8910aws Is not drying properly. -I tested the Heating element to be 13ohms. -I left a voltmeter on durning its run and drying cycle, showed no voltage tested AC & DC -Tested the thermosensor to show good (0 ohms). -Kept a food temperature probe clipped onto the heating element , water temperature was around 120deg, at one point the temp. started to rise to about 130, but there was still no voltage to the coil, checked AC & DC. Do you think the relay contacts on the control board? Or something else I replaced the control board a few years ago because of another issue, and its been fine till now. Any Help would be great! Best regards, Andrew
Answer Andrew, You will want to check to make sure that the wiring between the control board and the heating element and if this is good then it will be a faulty control board. Read More... Answered by AppliancePartsPros.com | Monday, November 9, 2020