Rick for Model Number WRF736SDAM14 Installed new ice maker (old one was getting error code E5 with service test 56). Now with new ice maker, I’m getting error code E3, and with service test 59, I’m getting 02, harvesting not completed
Answer Rick, with the unit set to test 58, the main control W10854027 would need to be tested for voltage output and it should have 120VAC when tested from the wire at connection P12 pin 6 to the wire at connection P1 pin 2. If there is not voltage, the main control has failed. If there is, the ice maker wire connection would need to be tested from the black wire with a white stripe to the white wire. If there is not voltage at this point, there is a wire failure. Read More... Answered by AppliancePartsPros.com | Sunday, April 10, 2022