Jim C. for Model Number 11066722694 My question is my Kenmore series 70 electric dryer will not switch on. Months ago i replaced the heat element and thermo unit. Today I replaced the push to start switch and the door switch, and still nothing. There is power to the dryer as the intertor light comes on. Can any one offer some suggestions??
Answer Jim, You need to check the dryer thermal fuse WP3392519. It is mounted on the blower housing, If the fuse "opens" (usually due to an overheating situation) It will not allow power to the motor, and the dryer won't start or run. This fuse is a "one shot" fuse and does not reset, it has to be replaced if it has an "open" circuit. Read More... Answered by AppliancePartsPros.com | Thursday, April 10, 2014