Reg for Model Number mhwe950wjo1 replaced water inlet flowmeter,water inlet valve, still doesn't fill and shuts off. your staff said to check water level pressure switch but don,t know how and said that if purchased cannot return if installed. any ideas before a possible wasted purchased. She also said no more mother boards will be made. thanks
Answer Hello Reg, Thanks for your question. The pressure sensor can be tested, using the wires at the main control board, after unplugging the power cord. With wires at PS8 unplugged from the main control board, and a meter set for continuity, test from wire at pin 4 to wire at pin 6, there should be continuity. Test from wire at pin 4 to the wires at pin 3 and pin 5, there should not be continuity, Test from wire at pin1 to wire at pin 2, the should not be continuity. if the readings are anything other than what's expected and there are no broken wires, the pressure switch WPW10249845 would very likely be a cause of failure. If pressure switch tests good suspect a board WPW10390921 failure. Read More... Answered by AppliancePartsPros.com | Wednesday, June 3, 2026