Steve for Model Number Maytag Bravos XL Dryer Model MEDB725BW0 Dryer has good air flow no obstructions. Runs 5 minutes or so and shuts off with check lint screen light on.
Answer Steve, it is recommended that the blower wheel belt WP8544742 is inspected to ensure that it has not excessively worn and the blower wheel is not congested with lint in the blower fan blades. From there, the outlet thermistor WP8577274 on the blower housing would need to be tested for resistance and it should measure 8.5-10.5K O at room temperature. If there is a lint build-up on the thermistor, it can cause improper readings when the dryer is running. The small terminal connector on the thermostat WP8557403 of the heating element should also measure 50KO at room temperature. If these things Read More... Answered by AppliancePartsPros.com | Wednesday, February 17, 2021