Jad for Model Number LER7646EQ1 Just replaced Thermal cutoff kit because it ran but did not heat. Worked great for a couple of days until today. I hear the timer clicking but does not run when start button is depressed. I tested the Timer motor and get a reading around 2.37 on the meter. I've been a customer for a while and I look forward to your response. Thanks JD
Answer Jad, If you're reading 2.37 ohms across the wiries to the timer motor, it's OK. At this point, you'd want to test the door switch WP3406107 for a "closed" circuit, white to blue with the plunger depressed, and then the test thermal fuse WP3392519 located on the blower housing for a "closed" circuit,with the wires off as well. Thanks and Good Luck Read More... Answered by AppliancePartsPros.com | Thursday, April 12, 2012