Robert L Lake Charles , LA December 16, 2016 Appliance: Model FTQ3531WUX The clock/cooking temp face was unreadable I replaced the Pcb Main Assy, in other words, the computer board that houses the clock face and cooking temp face. It really is an easy fix for those who have any mechanical abilities. Mention was made by another about the "flex cable" on the left of the board. NOTICE, the little black keeper does not completely remove, it only slides up just a touch and then the "flex cable" can be gently pulled from the connector. The only other connections that gave me a puzzle for a moment was the 2 "metal" connectors on the bottom left of the board. They have a tiny "release" within the clip, under the plastic hood, that must be pressed in order for the clip to release from the lug. Other than that, anyone with reasonable skill should be able to do this themselves. 7 People found this story helpful Do-It-Yourself Rating: Repair Time Estimate: Less than 15 minutes