William S Ladson , SC May 03, 2014 Appliance: Electrolux Electric Dryer EIED55HIW0 E63 error code and dryer overheating Replaced exhaust thermal cutoff switch. Sears wanted to charge for a service visit + parts and labor. $17 part, $6 shipping and I received the part the following day. Repair complete in less than an hour at a fraction of the cost. Thanks appliance pros. Read More... 22 People found this story helpful Do-It-Yourself Rating: Repair Time Estimate: 30-60 minutes Tools: Screwdrivers
Amanda N Louisville , KY November 02, 2014 My frigidaire affinity dryer should the error code e66 My husband fixed the dryer after taking apart the front and drum of the dryer apart. We could not find the part anywhere. After ordering the part from amazon, and being told it wouldn't arrive until another week, we ordered from appliance parts pros. It arrived within 2 days and my husband had the dryer working very quickly. Read More... 9 People found this story helpful Do-It-Yourself Rating: Repair Time Estimate: 15-30 minutes Tools: Screwdrivers
Bertram D Cumberland , RI August 16, 2015 Appliance: Frigidaire Electric Dryer LAQE7077KW0 Thermal limiter was burnt out Removed rear cover and exhaust pipe. unplugged and removed thermal limiter, location was right on the parts list. installed new limiter and vacuumed out exhaust vent which was clogged with lint. easy fix with the correct info provided on you website. thanks Read More... 7 People found this story helpful Do-It-Yourself Rating: Repair Time Estimate: 30-60 minutes Tools: Screwdrivers
William S North Tonawanda , NY December 20, 2015 Dryer code door open Replace thermos limiter on exhaust tube. Read More... 3 People found this story helpful Do-It-Yourself Rating: Repair Time Estimate: 30-60 minutes Tools: Nut Drivers, Screwdrivers
Timothy K Ashland , KY May 06, 2019 Appliance: Model FASE7074LNO Problem was that dryer was saying door was open when it was closed I did a continuity test on the outlet there fuse ( there was no continuity) then ran a continuity on the control thermistor( no continuity) when I received the new parts the new control thermistor also had no continuity. Installed both fuses and dryer started. On a dryer always run a continuity test an u will almost find your problem Read More... 2 People found this story helpful Do-It-Yourself Rating: Repair Time Estimate: 1-2 hours Tools: Screwdrivers