Gaspar D Summerfield , NC December 31, 2015 Convert microwave from recycling vent to an external vent system We followed the manufacturer's instructions about re-positioning the fan motor and installing the vent damper (easy). We constructed a duct system from the microwave to the outside of the house (challenging). We used 3.25" x 10" metal duct to start the system through the wall behind the microwave, where we added framing to reinforce a cut stud. We ran the duct up a closet wall and through its ceiling into the attic. We had to make an offset duct piece from 3.25" x 10" metal duct to clear a ceiling joist. To align parts in the attic, we transitioned to 7" round duct and back to 3.25" x 10" duct at the rectangular wall cap through the side of the house. We modified duct joints as necessary and slanted the horizontal ducts downward toward the wall cap so any condensation would run out of the wall cap rather than accumulating or dripping onto ceilings. We installed metal straps to support the ducts and secured all duct joints with sheet metal screws and metal duct tape. We may add duct insulation wrap to exposed ducts. Read More... 11 People found this story helpful Do-It-Yourself Rating: Repair Time Estimate: 2+ hours Tools: Adjustable Wrench, Nut Drivers, Pliers, Screwdrivers, Socket Set
Robert H Farmingville , NY April 05, 2014 Appliance: Model GE MICROWAVE Microwave needed external exhaust hookup. Purchased damper assembly on Tuesday, had it shipped regular shipping and received it the very next day,Wednesday, WOW ! Very happy to be able to install it on Thursday. Benefit, no delay and the customer was delighted... Read More... 6 People found this story helpful Do-It-Yourself Rating: Repair Time Estimate: 15-30 minutes Tools: Screwdrivers
Jg-Sell S Plymouth Meeting , PA May 29, 2017 Appliance: Model GE JVM1650WB008 Needed to vent microwave outside I bought a GE Microwave from someone to replace unit that had gone bad. Repair was easy; 1st I removed to screws at top and flipped motor assembly so blowers were facing up, then I slid hood damper assembly in at top, then reinstalled microwave and now when I press the vent button, the exhaust goes outside thru duct work. Very East!! Read More... 3 People found this story helpful Do-It-Yourself Rating: Repair Time Estimate: Less than 15 minutes Tools: Screwdrivers
David I Irwin , PA October 31, 2014 Replaced recirc exhaust on microhood with outside exhaust Purchased vent adapter from appliancepartspros.com. Successfully installed adapter in exhaust line. Read More... Do-It-Yourself Rating: Repair Time Estimate: 15-30 minutes
Paul S Clive , IA December 13, 2015 Needed damper for re installation of microwave Attached damper and installed unit Read More... Do-It-Yourself Rating: Repair Time Estimate: Less than 15 minutes Tools: Screwdrivers