Roy September 26, 2017 I have a Frigidaire upright freezer, after a while the high temp light comes on and then the alarm sounds if I press the reset the alarm stops and the freezer starts up again, sometimes I have to change temp settings to make it work. Or if its been powered off for a while then it fires up but eventually the alarm sounds again. would this be the control panel or the capacitor causing problem?
1 Answer Hello Roy. Based on the information you provided, the board is bad and will need to be replaced on the unit. Thanks. Read More...
Drew September 21, 2017 for Model Number Lffu14f5hwh I have a Frigidaire upright freezer that stopped cooling. I tested defrost thermostat changed the startup relay and made sure drain hose clear. It sounds like compressor is running and fan works but still won't get cold. The coils by fan aren't getting cold. Controll panel? Thank you
1 Answer Hello Drew. Based on the information you provided, it sounds like the sealed system has failed and you will need an HVAC tech to come out and repair the unit. Thank you. Read More...
Buck September 19, 2017 I have accidentally locked my freezer temp at 3. How do i take the lock off of control panel?
1 Answer Hello Buck, you'll want to hold down the "alarm reset" button down for 3 seconds. Depending on the style of display you have, it will either display a "U" for unlock or the "control lock" light will go off. Thanks! Read More...
Cathy September 12, 2017 for Model Number FFU21F5HWG Plugged in does not sound like it is running. Display shows an F and if I press cancel. It goes to 0? Have unplugged to try and reset nothing different.
1 Answer Cathy, This issue will most likely be caused by a faulty thermistor which will be part number 297018400. Read More...
Eddie September 12, 2017 My frididaire freezer is holding the correct freezing degree but the control board tells me the door is ajar..I checked the rubber seal and no air is escaping...it continues to beep and tells me door ajar. How would this problem be fixed?
1 Answer Eddie, With this issue the User control board will be the most likely cause for the unit showing door ajar with the door closed and the light switch working. Read More...
Mihaela August 15, 2017 I have an upright Frigidaire freezer and keeps showing "power loss" and "door ajar" and temperature is going up. I can reset it only if I unplug and plug back in but next day it does the same thing. It happened a few times before and was working fine for a few weeks but the past few days is doing it constantly. I made sure is leveled and the door is closed and still does it.
1 Answer Hello Mihaela, While this sounds like a control board issue, we cannot tell what controls you have without the units' model number from the I.D. tag. I'm sorry but we will need to ask you to post a new question including the model number from your units' I.D. tag so we can recommend parts that can be guaranteed to work properly on your unit. Thank you for your patience and understanding in this matter. Read More...
Steve August 10, 2017 for Model Number FFU17F5HWU i have an upright frigidaire freezer i went to get some food out of it and the alarm was beeping and everything inside was defrosted... when plugged in everything runs but won't freeze/get cool and flashes "E" code
1 Answer Hello Steve. Check and see if the compressor is running. If not, then you will need to replace the control board. If it is running, then you have sealed system failure and will need an HVAC tech to come out and repair the unit. Thanks. Read More...
James August 08, 2017 for Model Number ffu21f5hww My freezer is reaching 3-4° but the temperature is set on 7° and the freezer runs all the time. What part should I be looking at to correct the problem? Thanks
1 Answer Hello James, This is most likely a glitch in the programming of the control 297370600 which would require replacing the part. Read More...
Camillo August 02, 2017 for Model Number GLFH21F8HWD I have a Frigidaire Upright Freezer. After a recent lightning strike the freezer has been acting up like shutting down and I had to reset it by unplugging it. It finally stopped all together so I ended up replacing the control board part # 297366306 and it started up immediately. All was great until I noticed that the digital temp on the board was reading 85 degrees and not going down. I checked the temp inside and the temp was going down fine. Coils didn't appear to be overly frozen and things looked fine. I decided to change the thermistor. That didn't solve the problem. Any ideas what else it could be. Could the new board be faulty and is that normal if so.
1 Answer Camillo, No this is not "normal" it make take a few minutes for the display to "adjust" and display the correct temperature, but not like you're describing. Before you replace the control, check the wiring harness at the bottom of the freezer door. Make sure there aren't any loose or damaged wires / connections. Replace the control again, if all's OK. Read More...
Jim July 28, 2017 for Model Number LFFU14F5HWH Is there a way to test Frigidaire 297370600 User Control Board! The freezer runs continuous, temp in freezer is -3 degress suction line is iced over. The heater / defrost circuit is closed, but no defrost! The Thermistor resistance @ -3 degrees is 82K, I need a temp / resistance chart. Thanks, Jim
1 Answer Hello Jim. Disconnect the wiring harness fromthe electronic module that goesto the thermistor and thetemperature control. Measure theresistance between the red wire andthe gray wire. If the meter read shorted or open the thermistoris defective.If the meter reads between 50,000 and70,000 ohms the electronic module is defective. So based on your reading, the board needs to be replaced. Read More...