Jim April 09, 2017 for Model Number LFFU14F5HWC The freezer runs, the compressor is running, the unit cools to around 28°F. The Hi Temp light comes on and the alarm sounds. I unplugged the unit to reset it with no luck. I emptied it and let it defrost completely. Water was dripping from the bottom of the door, is that normal? Is this likely a control unit malfunction or a compressor failure?
1 Answer Hello Jim, Water dripping from the bottom of the door during warm-up while unplugged is normal. You should remove the rear wall of the freezer and observe the frost pattern to determine the units' issue. The frost pattern should be established after 24 hours of run time so the diagnosis can be accurate. Read More...
Marie March 14, 2017 for Model Number FFU14F5HWF I noticed my light and temp display went out..then noticed my freezer not keeping things frozen...the compressor is still running fine
1 Answer Hello Marie. It sounds like the board is bad and will need to be replaced on the unit. Read More...
Debbie Bowman March 12, 2017 for Model Number LFFH21F7HWA The temp. in freezer keeps going up, then shutting down. I unplug it then it starts up, control panel flashes power loss. Could it be the fan ? I can't figure out where the fan is ?
1 Answer Debbie, The 5304504914 / 5304504914 motor, is located inside the freezer, behind the lower back wall/evaporator cover. If the fan does stop running, the interior will start to warm and the temperature will rise. When you remove power to the freezer, you will get the power loss signal in the display, this is normal. Once you check the fan motor, if it is OK, you'll want to consider the 297235200 / 297241900 Ele. Control Assembly, it's more likely to be the issue. Read More...
Anna February 19, 2017 for Model Number FFU14F5HWN My freezer was working fine until i tried to wipe off a mark on the UP symbol. I noticed the display started showing random signs. I tried to press the UP, DOWN, and ALARM RESET buttons, but nothing changed. The inside lights were still on, but the freezer wasn't working.
1 Answer Anna, Unplug the power cord or remove power to the freezer for a few minutes (3 to 5), then restore power and reset the controls. If the problem remains or persists, replace the user control board. Read More...
Andy B. February 13, 2017 for Model Number FFU14F5HWN I was having a electrical issue at the plug source and removed the short and fixed it, but after that I noticed my freezer stopped working and the control board was on but not responding properly to my commands and the LCD display wasn't correct and erratic. The light still comes on but no compressor power at all. From what I read, the control unit sounds like it's bad and if that's the case, is there anyway to run the freezer, by passing the control unit?
1 Answer Hello Andy, I'm sorry but there is no way to bypass the control on this unit so it will operate normally. You will need to replace the control 297370600 to reestablish normal operation. Read More...
Susan February 10, 2017 for Model Number LFFU17F5HWM on the outside of the freezer the red light on the panel keeps saying high temperature. I unplug it and plug it back up and nothing happens Not freezing at all. Compressor seems to be running but not freezing at all. what could this be?
1 Answer Hello Susan. If the compressor is running, and the unit is not cooling, you have a sealed system failure and will need an HVAC tech to come out and repair the unit. Read More...
Bob January 30, 2017 I have a frigidaire upright with control panel on the door. It suddenly stopped working. The red power loss light and door ajar lights are lit as well as everything on the temperature display (both numbers, hrs, duration) I unplugged it and left it off for around 12 hours. Plugged it back in and waited.... nothing. Still the red lights lit up and nothing works. Not even the inside light.
1 Answer Hello Bob. It sounds like the control is bad and will need to be replaced on the unit. Read More...
Tony January 30, 2017 for Model Number FFU14F5HWF Freezer high temp light was lit. I unplugged and waited about 30 minutes then reinstalled. Light went out, but freezer still warm on the inside after 24 hours. Freezer constantly running and not freezing. What could be the problem?
1 Answer Hello Tony. You will need to check the compressor on the unit and see if it is working properly. Here is a link to our Repair Forum, this is a free service to our customers. Use this link to access the repair for your question. http://forum.appliancepartspros.com/refrigerator-freezer-repair/193358-freezer-fridge-not-cooling.html Read More...
Bruce January 28, 2017 for Model Number LFFU14F5HWC The interior light on this Frigidaire upright freezer blinks on at a 1-second interval when I open the door. I noticed this after the interior of the freezer got really warm. I unplugged and re-plugged the freezer and it now appears to be cooling properly and has been functioning for 24 hours. However, the interior light does not stay on when I open the door. It just blinks once a second. What is the most likely problem and remedy?
1 Answer Bruce, With this unit the user control board will cause the light to flash in the freezer and would need a new control board. Make sure that the lights are tightly screwed in first. Read More...
Phil January 18, 2017 for Model Number LLFU14F5WA frigidaire upright freezer the control board lights / numbers went dark freezer still runs but cant tell at what setting. the inside light went out at about same time. probably not related b Im guessing its the control board AP5318915 thanks
1 Answer Phil, Good guess, the interior light could be a coincidence, but the power to the bulb is also supplied through the control board. Before you replace the control board, check the wiring harness at the freezer door hinge, make sure there are no loose or damaged wires and the connections are tight, then replace the control board if all's OK. Read More...