Darren January 18, 2017 for Model Number 297370600 My fridge will not stop beeping i just want to eliminate the alarm how do I do so?
1 Answer Darren, Unfortunately the alarm is incorporated into the board and would not be able to disable the alarm. Would need to replace the board if there is no fault. Read More...
Misty December 01, 2016 I have a frigidaire stand up freezer and it reads door Ajar and power loss. Please help
1 Answer Hello Misty. It sounds like the control board is bad and will need to be replaced on the unit. Read More...
1 Answer Hello Marolyn. We will need your model number to help you with this. Please call 1-877-477-7278 or post your model number with a new question on the parts page. http://www.appliancepartspros.com/modelnumber_locator.aspx Read More...
Frank K November 07, 2016 for Model Number FFU21F5HWB Original control board p/n 297241800 failed and was replaced with 297370600. Freezer runs all the time and will not shut down on any setting. I purchased three of the replacement boards from three different suppliers and same result. I can unplug freezer and plug it back in and it will shut down . I have also replaced the thermistor and same results. Frank
1 Answer Frank, You will want to make sure that when you installed the board that you programmed it to the correct cubic footage size. If this checks ok then you would want to test the thermistor at the control board to make sure that it is good. It is possible that the wiring between the control board and the thermistor could also be faulty. This issue sounds like the control would be the issue but maybe not getting set for the correct cubic footage is most likely. Read More...
Terryh October 31, 2016 for Model Number FFU21F5HWC Light is on not freezing and partial numbers on display.
1 Answer Hello TerryH. It sounds like the control board 297370600 is bad and will need to be replaced on the unit. Read More...
Mark September 27, 2016 for Model Number Ffu21f5hwy I bought a new control panel # 297370600 for upright freezer model FFU21F5HWY and it binks E and 8. Please help with this error code. Thank you
Mark September 27, 2016 I just got a new control panel part# 2973706000 put it on freezer and the display blinks an E and an 8. Please help
1 Answer Hello Mark. We will need your model number to help you with this. Please call 1-877-477-7278 or post your model number with a new question on the parts page. http://www.appliancepartspros.com/modelnumber_locator.aspx Read More...
Kerry September 13, 2016 for Model Number Fridgidaire standup freezer I have a Frigidaire standup freezer. The unit stopped working and the control unit PIN 297370600 is showing partial letters and numbers as well as the up arrow is not working. When I opened the door there were light black smoke markings on the inside of the door at the top corners and some on the gasket at the top corners. When plugged in the control panel gets power with the above noted happening but also no power to the inside light, bulb looks good. What concerns me is the light black smoke as I have inspected everywhere and cannot find the cause. If I replace the control unit and it still does not work I am out a couple of hundred dollars. Any help would be appreciated thanks as this unit is only about 3 to 4 years old.
1 Answer Kerry, This issue would most likely be caused by the user control board 297370600. Here is the link to our return policy. http://www.appliancepartspros.com/customerservice/returns.aspx Read More...
Kathy September 10, 2016 for Model Number LFFU14F5HWA My control panel is set on 4. I noticed after a power outage that the freezer now runs continuously. I unplugged it and plugged it back in and that didn't solve the problem. Also, when I set it on 0 it doesn't turn off. If I lower the temp, it doesn't stop running either. It seems to be stuck,or unresponsive. Any suggestions?
1 Answer Kathy, This issue would be caused by a faulty control board which is part number 297370600. Read More...
Bill August 06, 2016 for Model Number LFFU17F5HWH We have an upright Frigidaire freezer with a high temp (red) light. It sounds like it's running but it's not freezing. What could it be? Do I need to replace the circuit board? THANKS!
1 Answer Hello Bill. If the compressor is running and the unit is not cooling, you will need to have an HVAC tech come out and repair the unit. Read More...