Terry O June 12, 2014 for Model Number LRA187MT2 The controller is in the Auto Mode but when it reaches set-point the unit won't shut off. Can raise the set-point but the unit still won't shut off.
1 Answer Hello Terry. Check the thermistors and see if they are good. If so, you will need to replace the control board on the unit. Read More...
Bruce@Bbkona.Com July 01, 2013 for Model Number LRA187MT2 My Frigidaire window AC has a fault code AS. The manual says it is a 'sensor failure'. Is there any way to tell which of the two sensors failed? I ordered both, and got the Ambient Sensor,5304471276 but the other one is 'backorder' and wont be here for another week. It is a job to change out and I dont want to do it twice if I need the other one. thanks. bruce brooks