1 Answer

Model GSL25JFPCBS, If you locate the original part number then it can still be used otherwise it will change to the new part number of WR87X10226.

Read More...

1 Answer

Hello Eugene. It sounds like you may have a defrost problem with the unit. If so, you will need to test the defrost heater and the defrost thermostat. They should read closed for continuity when cold. You can test this with a multi-meter TJMA-DMT3. I will include a link at the end to assist you how to use the multi-meter if needed. If both parts are good, you will need to replace the defrost timer. Once the problem is repaired, you will need to thaw out the ice on the coils before the unit will operate properly. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html

Read More...

1 Answer

Hello Rodrigo. You will need to replace the compressor in the unit. That is the issue with the unit.

Read More...

1 Answer

Hello Danielle, If the unit is maintaining proper temperatures and no frost accumulation is occurring on the rear wall of the freezer compartment, this is considered to be normal operation of a 134a unit. The pressures are so high in the 134a systems that the lines make all sorts of weird noises. While most customers do not like this, there is basically nothing that can be done short of ignoring the noises.

Read More...

1 Answer

Hello Susie. Based on the information you provided, it sounds like you have a low freon issue or restriction. You will need an HVAC tech to repair the unit.

Read More...

1 Answer

Hello Liz. Based on the information you provided, it sounds like the main control board WR55X10942C is bad and will need to be replaced on the unit.

Read More...

1 Answer

Hello Syed, The clear liquid you saw under the compressor was the water from when unit goes through a defrost cycle. The base where the compressor is located is also used as a drain pan and will collect water on a daily basis and evaporate from the heater of compressor and fan blowing across it.

Read More...

1 Answer

Hello Diane. In order to complete the entire install of the compressor kit WR87X10226, the unit must be evacuated and charged by a HVAC technician.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • Over 2.1 Million Parts In Stock Over 2.1 Million Parts In Stock
  • 2 Day Quick Delivery! 2 Day Quick Delivery!
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Google Trusted Store Google Trusted Store