Customer Questions and Answers for Dispenser Switch by Ge

Best Seller
Manufacturer Part
4.89 (64)
By: Ge
Part Number: OEM6202560
Manufacturer Part Number: WR23X366

Questions & Answers

For Ge Dispenser Switch (Part Number: OEM6202560)

1 Answer

Dave,

Most likely the issue would be caused by the dispenser switch WR23X366. A way that you could check this is to move the dispenser to cube and if it is trying to dispense ice on its own then the switch would be the issue.

Read More...
James for Model Number GSHS6PGYAESS

I have a 3 year old GE refrigerator (GSHS6PGYAESS) and the water dispenser will start to work but then after a couple seconds it will start to sputter like the water flow is being cut off. I can hear a noise from the rear of the fridge (like clicking and chugging) up behind the water filter. The problem was only once in a while at first but now its constant. Everything else, including the ice maker and dispenser, is functioning normally. I have replaced the filter, used the filter bypass and the replaced the water valve and the problem still exists.

1 Answer

Hello James. It sounds like the filter head is bad and will need to be replaced on the unit.

Read More...

1 Answer

Hello Dan. If there is power to the motor, and it does not run, replace the motor in the unit.

Read More...
Christopher for Model Number TFX20JR

For the second time in less than two months, the water will automatically start dispensing without even touching the switch or pressing the dispense button creating a mess. Thank God somebody was home when this had happened otherwise who knows how long it would have run for. It still created a mess in the kitchen until the water supply was shut. I turned the water supply back on and it seems to be functioning ok but I'm nervous that this will happen again. I already replaced the solenoid in the back where the water line comes in but I'm now beginning to think that it is the dispensing switch but would like to know for sure before purchasing. Any idea?

1 Answer

Christopher, are you sure there is not a water pressure issue on the water supply, or that your not attached to a reverse osmosis filter sytem ? low or fluctuating water pressure can cause a fill valve solenoid to open. The next check is the wire harness at the door hinge, check and make sure there are no loose connections and chafing on the wires. Then replace the actuator switch WR23X366. Thanks

Read More...

1 Answer

Hello Stan,

This can be caused by a bad water inlet valve WR49X10043, low water pressure, or air in the line. First, if it's been a while since the water filter has been changed, I would change the filter. Then I would remove the water line from the back of the unit and check the water pressure there. If it's low, it could be that the water line originates from a self tapping saddle valve. If this is the case, you need to slide the saddle valve over a bit and drill the pierced hole out to a full 1/4 inch hole.

Read More...

1 Answer

Hello David. The dispenser switch WR23X366 is the perfect place to start. In the process of getting there remember that if ice has been dispensed into a glass filled with liquid, the liquid will splash up into the area where the paddles and linkages are located. This can cause the linkages to stick, which is the initial complaint. In light of this information, keep in mind that in many cases simply cleaning the area of sticky residue corrects the issue. Hope this helped!

Read More...

1 Answer

Edna, You'll need to dismantle the dispenser assembly in order to check the switches and mechanism, here are some basic instructions :
" The dispenser assembly consists of the interface, display board, dispenser shield, and duct door functioning parts. The dispenser interface can be removed to access the display board and the dispenser shield mounting screws. The interface is held in place by 4 tabs that hold it to the dispenser recess. To remove the interface, it is necessary to grasp the bottom lip of the interface on either side and gently pull it towards you. There are 3 wire harnesses connected to the display board.The dispenser shield can be removed to access
the cradle switch, duct door, duct door solenoid, and dispenser LED lights. The dispenser shield is attached to the dispenser recess with 4 Phillipshead screws." Thanks and Good Luck

Read More...

1 Answer

Hello James. If the unit is leaking and there is no air in the lines, you will need to replace the water valve WR57X10051. Hope this helps.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google