Roger February 24, 2019 for Model Number GE DZRS483DFG This GE Gas dryer takes a very long time to dry a load (even in timer mode). The vent is clear. The gas turns on and ignites and shuts off after a few seconds. It continues to cycle off and on. The high limit and inlet thermostats test OK (9K ohms) at room temperature. Is this a Gas solenoid (WE14X215) issue?
1 Answer Roger, Based on your post information and descriptions, yes, the gas valve coils are the more likely issue WE4X692 and WE4X693 . The WE14X215 Gas valve assembly is a good option as well. The model number you supplied is incomplete or incorrect , so we're using the part number you supplied as a cross reference for the parts you may need. Thanks, Read More...
Jason January 25, 2019 for Model Number DPSE810EG1WT It runs, but doesn't dry. So far I've found: The safety thermostat and hi limit thermostat on the element housing show 0 ohms. The inlet thermostat shows 128 k ohms at around 65 degrees F room temp. The elements themselves show 20 on the inner and 20.6 on the outer. On the blower side of things the safety thermostat looking one shows 0 ohms and the center outlet thermistor is around 140 k ohms.
1 Answer Jason, The outlet and inlet thermistor should not have a resistance of the inner terminals being 140K ohms of resistance and should be around 10K ohms. Read More...
Tom January 17, 2019 for Model Number GTDS560EF5WS There are three wires going to the heating element in this dryer. When I opened it up, I found one of the wires had burned off and was just hanging near the spade terminal on the right side. I replaced this terminal end on the wire and re-installed it. The dryer worked for awhile, the stopped heating once again. When I removed the drum, the wire was dangling again and the new connector looked like it had arched too. All of the of the thermostats check out for continuity. any ideas on where to look for the problem? Also I have cleaned all vents. If the element was bad, would it cause this connector to burn off like it is doing? Thanks for your help.
1 Answer Tom, you will want to first check the resistance of the element by checking from the purple wire to the blue connection with the blue wire removed. The element should read 21.8 ohms. You will then want to do the same for the white wire connection. If the element does not read this ohm, you have a bad element which could cause for more current to be needed to heat up the dryer properly. This can potentially burn out a wire. Another thing you will want to check for is to check that the connection is tight because if it is loose, it can cause arcing which will damage the wire connection as well. Read More...
Robert October 19, 2018 for Model Number GTD33EASK0WW Dryer is overheating, I replace all thermostats still overheating, can you help me please.
1 Answer Robert, You will want to check to make sure that the vent is clear as this would be the most likely cause for this issue if all the thermostats have been replaced along with the inlet and outlet thermistor. One thing you could try is disconnecting the venting from the back of the unit and see if it works properly and if so then the venting would be the issue. Read More...
Devin October 15, 2018 for Model Number Ge dc series dryer it has a power on off button digital timer display I start a mixed load and hit the start button after timing the cycle my wife went to check the dryer and it was off like it had finished the cycle the clothes where good and dry she loaded the next load and hit the power button to turn it on and the panel would not do anything I voltage tested the dryer plug and its working fine and I replaced the power cord with new one still nothing. I did ohm test what seems to be the safety thermostat would that the be the cause of no power
1 Answer Hello Devin, I'm sorry but we will need to ask you to post a new question including the model number from your units' I.D. tag so we can provide a proper diagnosis and recommend parts that can be guaranteed to work properly on your unit. Thank you for your patience and understanding in this matter. Read More...
Sb September 21, 2018 for Model Number DBVH520EJ3WW Today, my dryer stopped working properly. The lights on the controls still come on, the beeps are still audible and the dryer light still comes on when I open the door. However, when I press a button to start the dryer I hear a "click" yet the dryer (drum) does not start spinning. I've done some searching on the internet/YouTube, and it seems that it may be the inlet-safety thermostat, the inlet control thermistor or the high-limit thermostat. The problem could have been due to dryer overheating because of lint build-up in the venting, but I'm not positive about that. Based on what the dryer is doing, which of these three parts would you recommend I try to replace?
1 Answer SB, It would be recommended to test the thermostats and thermal fuse, check the door switch for continuity. Also check to make sure that the belt is not broken and if there is a broken belt switch then test it to make sure that it is good. If all this checks ok then the most likely cause will be the control board. Read More...
Eddy August 23, 2018 I have GE Gas dryer Model DBVH512GF0WW The unit will start, have heat during first few minutes, then heat dies down, but the drum will keep running (but cold) I made sure lint filter clean, and also clean the vent. What do you think might be the problem? Thermostat? how many different kind? I am seeing 2 here. Please let me know
1 Answer Eddy, Being that you have a "gas"dryer, the most likely issue is a set of weak gas valve coils 279834 Dryer Gas Valve Coil Kit. As long as you're sure the dryer vent is clean/clear all the way out to the vent hood. There is an inspection hole(peep hole) in the base of the dryer, use a mirror and observe the ignition process/sequence(you can also listen for the gas to ignite). Allow the dryer to run and heat for 10 or so minutes, then check the process. Read More...
Nikole August 09, 2018 We have a GE model # DCVH640EJ0WW Dryer was over heating and dryer would not start. Now dryer wont start at all. Does this model have a thermal fuse? If so where is it located
1 Answer Nikole, the safety thermostat is located on the left side of the heater, it will be located on the rear bulkhead. part number is [WE4M160] Read More...
Ouidah July 16, 2017 for Model Number GE, DPSE810EG6WT Dryer won't turn on. Control panel is dark. Drum lamp works when door is open. No problem with idler switch or belt. Can you help?
1 Answer Hello Ouidah. You will need to check and see if the thermal fuse is bad and if the door switch is bad. Either will prevent the unit from starting. Read More...
1 Answer Leandro, Unfortunately we would not have a maximum working temp on this control thermistor. Read More...