For Ge Washer Main Control Board (Part Number: OEM24164106)

1 Answer

Paul,

Thank you for your question. If the unit is giving error codes and it works properly in the service diagnostics, then this will be a faulty control board WH22X38697.

Read More...

1 Answer

Thank you for your question Douglas. While it could potentially be an issue with the main control WH22X38697, checking for any error codes would be recommended. This can be done by holding the start button down for 10 seconds while the unit is in standby. After 10 seconds, the LEDs should all turn on and the start button can be released. The pause and door lock LEDs should then constantly blink while any error codes should show up.

Read More...

1 Answer

Michelle, if there is not an indication of loose or damaged wires, this failure would most likely be caused by the main control WH22X38697.

Read More...

1 Answer

Brandon, the main control WH22X37840 would need to be tested for 120VAC at connection J101. If there isn't voltage, the power supply may need to be checked to ensure there is power at the outlet. If there is voltage, the connection J615 would need to be tested for 12VDC from pin 1 to pin 3. If there is not voltage, the main control would need to be replaced. If there is voltage, the user interface would need to be tested for 12VDC on the same wires at the user interface. If there is voltage present, the user interface WH22X34918 has failed.

Read More...
Mont for Model Number GE GFW550SSN2WW

When I run the error tests, the number 12 test, which is the one for the pump on this unit, the whole display goes black and never comes back on. I don't know if that indicates the board has a problem. When I run the test 14 for the spin test, the display goes black, but eventually the drum starts spinning, but I never see anything happen on test 12. During the time that the pump is supposed to be running, when I test the board for output on pins 2 and 3, there is no voltage. When I disconnect that plug from the circuit board and do an ohms test, I get 20.4 ohms on the pump motor. The manual says it should be approximately 19.5 ohms. I do a lot of service work on dairy equipment electronics and pulsator coils. If a pulsator coil was off that approximate value of .9 ohms, we would say that was within tolerance, but I am not sure if that applies to this pump motor. When I opened the pump, there was a small wire on the floor. I am not sure if it came out of the pump, but I think so. If so, that may have been stopping the pump. I used a cord and applied 120V to the pump motor, it seemed to run fine so I think the pump is probably OK. Would you recommend that I change the pump too?

1 Answer

Hello Mont, likely the drain pump had a failure at some point and damaged the circuits in the main control board, at this point both the pump motor and the main control board should be replaced.

Read More...

1 Answer

Lee,
Check the door lock, door switch, and water temperature sensor. Check harnesses and connections.
• If the above is checked well, replace the main control board.

Read More...

1 Answer

Mike, the main control WH22X38697 would communicate with the motor inverter control WH22X38837 when the inverter would need to operate the motor. There is a 120VAC supply that would go from the main control connector J506 to the inverter connector J101. There will also be 12VDC communication signals from the main control connector J101 to the inverter J301. If the main control is failing to send either voltages, it would need to be replaced.

Read More...

1 Answer

Mike, the pressure sensor of the main control WH22X38697 would not have a testing procedure aside from what can be identified through a diagnostic mode or through the process of elimination.

Read More...

1 Answer

No, but you can Text “PARTS” to 36534 and follow the prompts to get a copy of the instructions electronically.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google