Denis May 27, 2021 for Model Number RF18HFENBSR/AC Hello! inverter is flashing 4 times i replace it but same problem do you have an idea thanks for support
1 Answer Hello Denis, 4 flashes indicate the compressor has seized internally (locked rotor). Read More...
Jimmy Jones April 15, 2021 for Model Number RFG238AARS/XAA What is the reason when the inverter board red light is flashing one time, after I replaced the inverter board it worked great for about 6 hours then it stopped cooling again, no frozen ice maker lines and doors are closed Thanks for any help you can give
1 Answer Jimmy, The single flash indicates a starting error. Check the connectors on the inverter and compressor to make sure that there are good connections. If the connections are good and no loose or damaged connections then the inverter would normally be the issue. Since the inverter had just been replaced then the compressor would be the issue. Read More...
Steve April 11, 2021 for Model Number RS25J500DSG/AA-01 Several days ago the ice maker quit working. Then several days later I noticed that the freezer and refrigerator sides were not as cold as they should be. cleaned the condenser coils, opened the evaporator section to check the fan and for a frozen evaporator. Only the top of the evaporator was frosted. I checked the thermistors in the evaporator compartment and both we functioning properly. I saw no signs of refrigerant leaking (oil stains, etc.). I inspected the boards for obvious problems. when I first opened the compartment with the control boards it did have a hint of burnt smell. The driver board has a solid red light and there is some cooling. I've forced the compressor on and this does not make it cool better. Is this a variable speed compressor? Could the driver not be giving the compressor the proper speed command? The manual that I found on the internet was lacking in any PID diagrams so I am in the dark about how to check this or how the boards and control devices interact with each other. My thoughts are one of the following: there is a control device giving the wrong signal, the mother board is telling the driver to do the wrong thing, the compressor driver is not sending the proper signal to the compressor, or it is a r134 issue. Any help is appreciated.
1 Answer Steve, Based on the information provided it sounds as if you have a sealed system issue and would need an EPA certified technician to perform the repairs needed. Read More...
Jimmy Jones April 05, 2021 for Model Number RFG238AARS/XAA Not cooling at all , replaced inverter board still not cooling - there is no red light flashing
1 Answer Jimmy, If there is no light coming on with the inverter, check to make sure that the inverter board is getting power to it. If it is not then the main control board would be the issue. Read More...
Jesse March 20, 2021 for Model Number RS25H5111SR refrigerator runs but not cold at all. red light on invertor board solid. All fans running and compressor running
1 Answer Jesse, Check the cover in the back, if it has ice built up on the wall then either the defrost drain is clogged and backing up onto the coils or a defrost issue. You should have continuity through the defrost heater, thermal fuse, and bi-metal. If these test out ok then the main control board would need to be replaced.DA92-00624A Read More...
Eric March 18, 2021 for Model Number Samsung rs25h5111sr/aa Inverter board light is solid red. Freezer works, refrigerator compartment isn't cooling. Compressor is working. Tech says that I need a new control board. Is that correct?
1 Answer Hello Eric, /when the inverter board LED is on it indicates that the compressor is not operating properly. The forced operation mode should be initiated to determine the exact problem. This can be caused by the Freezer thermistor or the mainboard if the compressor runs in this mode. If not, the problem can be caused by the inverter board or the compressor. To enter the forced operation function, press the energy saver and fridge buttons at the same time for 8 seconds. The display should return to normal after 15 seconds in the ready mode. Once in the ready mode press any button to start a "pull-down" operation. when pull-down is entered, the compressor should start immediately. To exit the forced operation mode unplug the refrigerator from the wall outlet. Read More...
Peter March 18, 2021 for Model Number rs265tdrs/xaa 02 My Samsung fridge run but kept worm with temperature at 53 deg and 43 def in two compartments. Both boards have red blink lights 4 times. May the inverter board replaement resolve the problem?
1 Answer Peter, The inverter board flashing 4 times indicates that the compressor is locked up and would need to be replaced. Read More...
Joseph March 16, 2021 for Model Number PFSS9PKYASS Replaced compressor, red LED in the back is flashing 5X. Possibly inverter board, correct? Looked for inverter board part # DA41-00411C but cant find one. Is there a different/newer part #?
1 Answer Joseph, Based on the model provided the inverter board for your model is part number [AP5408759] https://www.appliancepartspros.com/ge-pba-inverter-wr55x10960-ap4508759.html Read More...
Ryan January 24, 2021 for Model Number RF268ABRS/XAA-0000 Everything works but the condensor fan, change the fan and still nothing. The red light on the inverter board is a solid red not blinking at all, what could be the problem. I have a fan blowing over the condenser and the refrigerator inside is very cold.
1 Answer Ryan, You will want to test to see if there is between 7 to 12 VDC getting to the fan. If there is not power then the main control board will be the issue. Read More...
Ed December 29, 2020 for Model Number RS265TDRS/XAA Ice maker is not working. Replaced Ice Maker, Replaced inlet water valve. No help. The water line from the valve to the ice maker is not blocked/frozen. The paddles on the ice make move occasionally, just no water getting to the tray. The rest of the fridge works fine. There is a burnt (electrical) odor from the control board area. Water dispenser works fine.
1 Answer Ed, it would be recommended that the main control DA41-00670C is fully inspected for any scorch marks when the appliance power cord is unplugged. Based on the information provided, it sounds like the control has a failure and inspecting it will identify if it is burning up and if a wire may have been affected. Read More...