Ann October 14, 2020 for Model Number RFG297AARS Will this power control board fit model RFG 297 AARS also shows: BOM name: RFG297 ABRS/XAA? The bar code number on the original power control number is: 06DA4100404DPR04S9J3219 Thank you
1 Answer Ann,Based on the model number provided the power control board for this model is DA41-00614F Read More...
Stephen March 31, 2020 for Model Number rf28hdedbsr I like so many others have an issue with the the coils freezing up and the ice build-up rubs the fan and eventually stops it from spinning...I manually have to defrost by unplugging as doing the factory manual defrost steps pops up the error code 25 E Do you know how to stop this or what part(s) are causing this issue? Thanks
1 Answer Stephen, You will want to test the defrost heater to make sure that it is good, test the defrost bi-metal and test the defrost sensor. If this checks ok then the issue will be a faulty main control board. Read More...
Greg S December 22, 2019 for Model Number RFG237AARS/XAA My Box stopped keeping temperature, I realized the condenser motor wasnt running. I bought a new motor and replaced it and the new motor wouldnt run either. After this I checked the voltage with my meter and the fridge was only getting 1.47 V. I need to know what board to replace, I know there isnt sufficient power coming in to the condenser motor and my fridge has multiple boards.
1 Answer Greg, The part that would be faulty would be the main control board DA92-00355B. Read More...
Patrick A August 09, 2019 for Model Number SamsungRF24FSEDBSR/AA Refrigerator not cooling, coils frost over in 3 - 4 weeks. . Discovered the fan was not running. Removed the fan and test ran it with 12v battery charger. Fan runs great. Checked for dc voltage at the connector terminal inside the fridge. Voltage is 1.46 volts dc, should be 12 volt, based on the fan motor requirements. I assume there is a 12 volt power transformer on one of the control boards, which has failed. Please let me know if my assumption is correct and if so, which board to replace. Thank you, Patrick Armstrong
1 Answer Hello Patrick, the manufacturer list part number DA94-02275B as the correct board for the model number supplied. Thanks! Read More...
Larry L. December 22, 2018 for Model Number RF323TEDBSR/AA-0001 The power went out recently and now the refrigerator has an error code “Pc Er”. I have tried unplugging the unit, then unplugged the connection on the top left door hinge. Reconnect plug then plug the unit in and it beeps for about 30 seconds and gives me the same message. On that screen, nothing has ever lit up. I read that the temp settings are supposed to be displayed, but nothing is there. Could it be a circuit board issue? Above was my original question which I was told that the Control Board was the probably the issue. So I bought the Control Board through APP and am still having the same problem as above. What else could be causing this?
1 Answer Hello Larry, 1) Display function when panel MAIN MICOM communication has an error.1-1) If there is no answer for 10 seconds after the panel micom received the requirement of communication, "Pc - Er" display on the panel PCB will be ON/OFF alternately until the communication error is canceled. (0.5 sec ALL ON, 0.5 sec ALL OFF alternately)1-2) “Pc - Er” display on the Pantry Room Display will be ON/OFF alternately until the communication error is canceled. (0.5 sec ALL ON, 1.5 sec ALL OFF alternately). In laymans' terms, this can be caused by a poor electrical connection between the main board and the display board, a bad main board, a bad display board, or a harness issue. Read More...
Larry L. December 15, 2018 for Model Number RF323TEDBSR/AA-0001 The power went out recently and now the refrigerator has an error code “Pc Er”. I have tried unplugging the unit, then unplugged the connection on the top left door hinge. Reconnect plug then plug unit in and it beeps for about 30 seconds and gives me the same message. On that screen, nothing has ever lit up. I read that the temp settings are supposed to be displayed, but nothing is there. Could it be a circuit board issue? Thank you..............
1 Answer Larry, If hitting any of the buttons on the display does not clear the code then this will likely be a faulty control board. Read More...
Joe J September 16, 2018 for Model Number RF4267HARS/XAA Possibly from nearby lighting strike refrigerator is dead . circuit breaker not tripped. Which component is the probable failure
1 Answer Hello Joe, it sounds like it more than likely could be the main board part number DA92-00146A. Thanks! Read More...
Joe F September 05, 2018 for Model Number samsung rfg237aars Have samsung rfg237aars problem with icing up on the coil, per your web page under the forums I replaced heater metal sheath with part number da47-00244Q which included the thermostat, part was a perfect fit, now 2 weeks later temp in refrig not as cool, today removed panel and again coil iced up, today I replaced the temperature sensor for the defrost heater so all components under the cover have been replaced except fan and temperature sensor that is attached to cover.What other component would cause this? Thanks for your assistance.
1 Answer Joe, The only other thing that would cause the unit to have a defrost issue would be the main control board part number DA41-00617B. Read More...
Twatte200 June 25, 2018 for Model Number RH25H5611SR/AA / 0002 Samsung refrigerator freezer side not circulating air no voltage at fan connector
1 Answer Twatte200, Make sure that when you test at the fan motor that the light switch circuit is not closed. this would have a reed switch and you could put a magnet on the door hinge cover to simulate the door being closed. The door has to be closed for the fan to operate. If there is sill not 7 to 12 vdc then the control board would be the most likely cause for this issue. Read More...
Donny May 15, 2018 for Model Number RH25H5611SR/AA Refrigerator come on but the compressor will not kick on. is it the power board.
1 Answer Donny, You will want to check to make sure that the inverter board of the unit. Check the light on the inverter board for a flashing light that may be flashing a certain way. This would be an error code and will need to check this. Read More...