Charles March 12, 2019 Samsung Front Loader WF218ANW Cycle fails with "Nd" not draining error. Trying any cycle even diagnostic spin test fails. Machine keeps cycling drain pump, never advances to spin.
1 Answer Charles, Check the drain pump to make sure that there is nothing clogged in it. Check the pressure hose to make sure it is not clogged. These would be the 2 most typical causes for this type if issue. Read More...
Jay November 28, 2018 for Model Number samsung wf377aag water not draining, changed water pump and checked for any blockage but still nothing. Can there be some sort of relay??
1 Answer Jay, Yes, The drain pump voltage circuit is completed through a relay on the main control board. You may want to check the wiring and connections between the new drain pump and the control board. You can also check for 120 VAC across the wires to the drain pump with the washer in a spin cycle. or Check the pump at CN10 (Pin6) on PCB to chassis ground. It should read 110~120VAC. If no voltage, replace the control board. Read More...
Dom October 11, 2018 Machine gets error code 4E after machine runs for about 10 mins.no water in machine
1 Answer Dom, We will need your model number to help you find the right parts for your unit. Please post another question with all your info included thank you. Read More...
Stanley July 29, 2017 What reading should I get on the Water Level pressure switch? I have an ohmmeter connected to the outside terminals and want to test it. I also want to check the inside terminals. I want to make sure that this piece is bad before I order the wrong part. Thank you.
1 Answer Stanley, You didn't post a model number or a problem or fault/error code, but Usually the pressure switch has three wires. you can disconnect the hose and remove the switch You place the meter leads on pin # 2(orange/common). and pin #1 purple you should read a closed circuit if the tub is empty. Then slowly,carefully blow into the switch where the hose was attached, until you hear a click then check between pin 2 orange and pin 3 pink should read a closed circuit. You can also check for the voltage at the main control board usually CN3 connector orange to purple should rad 2.5 VDC empty, and orange to pink should read 2.5 VDC full . Read More...
Rusty February 25, 2017 for Model Number WF409ANW/XAA Which part on your sight is the water level switch?
Derrald June 13, 2015 for Model Number wf419aau/xaa-0003 Which part on your site is the water level switch?
1 Answer Hello Derrald, For the model number you provided you will need DC96-01703B for the pressure sensor assembly. Read More...