Customer Questions and Answers for Dryer Electronic Control Board - No Housing by Frigidaire

Best Seller
Manufacturer Part
4.89 (64)
By: Frigidaire
Part Number: OEM20670792
Manufacturer Part Number: 134557200NH

This is the main electronic control board for the dryer, sold without the outer housing. It manages dryer functions including cycle selection, temperature regulation, and timing. Replace this board if the dryer won't start, stops mid-cycle, displays error codes, or if the controls are unresponsive - note that the existing housing from your old board will need to be reused.

More

Questions & Answers

For Frigidaire Dryer Electronic Control Board - No Housing (Part Number: OEM20670792)

1 Answer

John,

Based on this information it does sound like the issue will end up being caused by a faulty control board.

Read More...

1 Answer

Roy,

Based on the description of the problem it sounds like the issue would be with the control board. This sounds like a key that may be stuck or the board being corrupted. You would want to replace the control board part number 134557200NH.

Read More...

1 Answer

David,

When the unit stops working you will want to check the thermostats to make sure that they are showing continuity. If they check ok then the control would be the most likely cause for the issue.

Read More...

1 Answer

Hello Vern. The connectors have locking tabs on them. You press on the locking tabs to release them and pull the connectors off of the control board.

Read More...

1 Answer

Gio,

With the unit not heating you will want to check the thermal fuse and the high limit thermostat to make sure that they are working. If they check ok and you are not getting 120 vac to the heater relay then the issue will be a faulty control board.

Read More...

1 Answer

Hello Phillip,
Fld is the indication that the control board is in the Field test mode and r08 is reflecting the firmware revision number. You will need to press and hold the select and cancel buttons simultaneously for 6 seconds to take the board out of this mode.

Read More...

1 Answer

Chris,

You will want to check the control thermistor on the blower housing to make sure that it reads 50K ohms at room temp. If not then the thermistor is bad and would need to be replaced. If the thermistor checks ok then the control board would most likely be the cause of failure.

Read More...

1 Answer

Hello Peter,
If your wiring harness is not shorted and the heating element is not broken and contacting ground, the issue will have to be the electronic control board. The noise will be either the rear bearing, the idler pulley, or the front glides getting too hot.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google